CAPABILITIESBanking Terminal conformance testing/Smart Card simulation
- According to ISO/IEC 7816 1-4
- Electrical and logical protocol parameters adjustable
- Error simulation
Monitoring between terminal and Smart Card
- According to ISO/IEC 7816
- Display and analysis of communication on physical and protocol layer in individual views
- Synchronisation between layer views
Test Suites - IT³ EMVCo Level 1 Electrical Test Bench
Scope of Delivery- IT³ EMV
- IT³ Installation (CD-ROM)
- Analog Probe
- Keyboard/mouse
- Paddle set (needed for execution of conformance tests)
Platform (PC) Specification- MS Windows XP Pro
- Interfaces: Ethernet 10/100 Mbit, RS232, USB
- DVI/VGA graphics adapter
- DVD RW
Dimensions- W x D x H: 205 x 410 x 465 mm
- Weight tower: 13 kg (APR 0.6 kg)
CE/FCC approval class A: This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. |
|
Further OPTIONSIT³ Analog Scope
- Integrated 50 MHz digital storage oscilloscope for detailed electrical measurements and analysis
- Max. number of channels: 12 digital, 3 analogue
- Analogue voltage measurements (res. ~2.5 mV) contacts: VCC, RST, CLK, I/O
- Adjustable recording depth: 4 k - 256 k samples
2 trigger conditions supported
IT³ Viewer - Software for offline-viewing of IT³ EMV log-files
General Features
- Supported Smart Card voltage:
1.2 V / 1.8 V / 3 V / 5 V - Supported ISO/IEC 7816 protocols: T=0 and T=1
- Current or resistive loads on all contacts
- VCC contact DC load: 0 ... 100 mA
- VCC contact spike load: 10 ... 200 mA
- Input contacts (CLK, RST, I/O, VPP)
- Voltage range: -2 ... 10 V
- Impedance: min. 5 MΩ, max. 30 pF
- Timing analysis of transmitted signals:
- Rise and fall time: 20 ... 5000 ns (I/O, RST, VPP), 5 ... 2000 ns or 0,1 - 20 % of Tclk (CLK)
- Resolution: 20 ns (RST, VPP, I/O); 1.25 ns (CLK)
- Speed: max. 8 clock cycles/etu at 10 MHz
- Measurement of analogue electrical signals
- Voltage: -2 V ... 10 V
- Current: 0.1 - 5 mA
- Frequency: 0.1 - 6 MHz
- Duty-cycle: 30 - 70 %
|