UT³ Platform

Overview | Use Cases & Setup | Technical Data

CAPABILITIES

NFC simulation/testing

  • Support of all NFC modes: Card Emulation,Reader/Writer, Peer-to-Peer
  • Simulation of polling and listening mode for NFC-A, NFC-B, NFC-F
  • Simulation of PICCs and PCDs as per ISO/IEC 14443, types A and B
  • Support for higher bit rates (up to fc/16; 848kbit/s)
  • Hardware supporting Waiting Time Extension (WTX) Request
  • Configurable protocol/timing parameters
  • Hardware supports RF Analogue testing

SWP and HCI simulation/testing

  • According to ETSI TS 102 613 (SWP),
    and ETSI TS 102 622 (HCI)
  • Adjustable logical SWP/HCI protocol parameters
  • Error simulation
  • S1/S2-signal at C6 contact:
    - Adjustable current value for S2
    - Measurement of voltage (S1) and current (S2)
  • Advanced SWP test features
    - Extended bit duration
    - Support for selective reject s-frame    (SREJ)
    - HW analogue SWP testing

Monitoring and analysis

  • NFC Forum digital protocol and activity, LLCP
  • NFC Forum application protocol: NDEF, RTD
  • All NFC Forum tag types
  • ISO/IEC 14443 (A/B)
  • ISO/IEC 18092
  • Proprietary contactless protocols B', MIFARE and FeliCa
  • Display and analysis of protocol specific information in synchronised views: Physical, Protocol, Application, Logical Link, Summary and Info view
  • Search and filter within the different views
  • Generation of comprehensive reports
  • Various on-the-fly protocol checks
  • Decoding of carrier and subcarrier
  • Timing measurements of Frame Delay/Waiting Time
  • Monitoring of bit rates from 106 kbit/s up to 848 kbit/s

TEST SUITES

Test Suites SWP/HCI

  • SWP test cases according to ETSI TS 102 694-1
  • HCI test cases according to ETSI TS 102 695-1
    and ETSI TS 102 695-3

GENERAL FEATURES

  • Supported Smart Card voltage:
    1.2 V / 1.8 V / 3 V / 5 V
  • Supported ISO/IEC 7816 protocols: T=0, T=1
  • Supported IC-USB modes: ICCD, Ethernet Emulation Module, Mass Storage
  • NFC: Feedback dialogue for optimal antenna positioning
  • Time measurement performance:
    - Resolution (contactless): up to (8fc)-1
    - Resolution (contact based): 10 ns
  • Measurement units: etu, second, CLK cycles
  • Time-synchronisation interfaces
    - High speed COMPRION SyncBus
    - Trigger out: connection between Analog Scope and xternal oscilloscope (1 V signal level at 50 Ω)
  • COMPRION Monitoring Remote Control: start/stop monitoring remotely
  • PCD output
    - Pmax 1W into 50 Ω impedance
    - Frequency range 13.56 MHz ± 3.75 MHz
    - Frequency resolution < 24 mHz
  • COMPRION Remote Simulation Server

 

 

 

FURTHER OPTIONS

Analog Scope

  • Integrated digital storage oscilloscopes with configurable sample rate of up to 100 M samples/s in contact based operation, and up to 4fc in contactless operation mode
  • Detailed timing and value measurements
  • Analogue voltage measurements on contacts VCC, RST, CLK, I/O and SWP
  • Analogue current measurements on contacts VCC and SWP
  • 2-stage cascading trigger definition
  •  Retriggering: multiple recording of samples initiated by defined trigger condition
  • Configurable sample rate: Resolution per sample: up to 14 bit
  • Record length up to 32 M sample points in contactless and 256 G sample points in contact based operation mode
Analog Scope Viewer
  • Visualisation of the analogue signals (e.g. modulated carrier amplitude, envelope signal)
  • Display of up to 8 digital channels in contactless and up to 16 digital/2 analogue channels in contact based operation mode
  • Signal/frequency analysis
  • Quick measurements
    - Modulation index
    - Waveform characteristics
    - Frequency spectrum
    - Fall/rise times
    - Peak-to-peak
    - Top/bottom
    - Duty cycles
    - Overshoot, Undershoot
    - Low Level, Mid Level, High Level

COMPRION MoVie

  • Viewing software for  sharing log files traced with COMPRION monitoring products without need of connected hardware

NFC DC Measurement

  • Two measurement channels
    - sample rate 100 MHz
    - resolution 14 bit
    - Input impedance: BNC 1MΩ/15pF; MCX 10 MΩ/10pF
    - Input measurement range: ±2.50V up to ±25V
  • External Trigger input
  • Trigger out
  • LEDs to indicate active channel, selected input range, hardware status

DIMENSIONS

  • W x D x H: 450 x 375 x 175 mm
  • Weight: 14 kg

SCOPE OF DELIVERY

  • UT³ Platform
  • UT³ Analog probe
  • Analog Flex Probes types A-D
    (terminal connectors)
  • Antenna - T - Type 01
  • Keyboard/mouse
  • Mounting Material for 19" Rack
  • Powercords (EU,US)
 